Battery runtime
Published
Estimate ideal runtime from battery energy, usable capacity, efficiency and load. Start from watt-hours or use the battery’s voltage and amp-hours. Apply usable capacity and conversion losses before estimating how long the battery can power a steady load.
Free to use. No email or account required.
Bookmark
Bookmark this tool
Save this link in your browser’s bookmarks.
Paste this link into the address of a new or existing bookmark.
On desktop, drag Battery runtime to your bookmarks bar.
Only the tool’s link is shared. Your inputs and results are not included.
Share
Your inputs
Edit the example inputs to match your task. Results update as you edit.
Calculations run in your browser. Inputs are not saved or sent to analytics.
How it works
Formula
- Supported input limits: : 0 ≤ x ≤ 1,000,000,000,000; : 1e-12 ≤ x ≤ 1,000,000,000,000; : 0 ≤ x ≤ 1,000,000,000,000; : 0 ≤ x ≤ 1; : 0 ≤ x ≤ 1; : 1e-12 ≤ x ≤ 1,000,000,000,000
Input and formula key
Your result
Complete the inputs to see your result.
Sources
- EIA — watts and watt-hoursSources reviewed: 2026-10-06
Assumptions and limitations
Ah requires the battery’s voltage to estimate Wh. Usable fraction and efficiency separately reduce delivered energy before division by a constant load. Aging, temperature, discharge-rate effects and inverter standby consumption are not automatically modeled.
How to use this tool
Set up the inputs
Choose rated capacity in Wh or calculate it from voltage and Ah. Enter usable fraction and efficiency as values from 0 to 1, then the constant load in watts. Keep battery voltage consistent with the stated Ah rating.
Understand the result
Delivered energy applies both reductions before dividing by load. The line shows ideal linear depletion at constant power, not battery voltage or a measured discharge curve. Temperature, battery age, inverter idle draw and changing loads can make actual runtime shorter.
Worked examples
-
Account for usable charge and conversion losses
- 500 Wh × 0.8 × 0.9 = 360 Wh; 360 Wh /100 W = 3.6 h
Frequently asked questions
Can I compare battery energy using Ah alone?
Only when the voltage basis is the same. In this model, 10 Ah at 12 V represents 120 Wh, while 10 Ah at 24 V represents 240 Wh. Equal Ah therefore does not necessarily mean equal energy or runtime. The conversion uses one entered voltage, without following its changes during discharge.
What if the stated capacity already includes a usable-energy reduction?
Do not apply the same reduction twice. The calculator always applies both the usable fraction and efficiency to the capacity you enter. If a particular reduction is already included in that capacity, use 1 for that factor. Apply another efficiency reduction only for losses not already included in the stated figure.
Does a positive runtime prove that a battery can run my device?
No. Energy capacity and power delivery are different quantities. This page estimates an energy budget at a constant load; it has no battery or inverter output rating, starting surge or cutoff input. A positive duration therefore does not establish equipment compatibility or whether the load can actually be started and sustained.
Processing and privacy
The calculation or transformation runs in your browser. The tool does not send its input values or generated output to an application server. Loading a page still makes infrastructure requests; optional analytics and Google consent messages have separate controls.
Privacy Policy. Privacy & preferences in the footer controls optional analytics.
Help and feedback
Consult the linked sources for definitions and reference data. Contact Support if you have a question or notice a problem.